  "opening": {
    "case_id": "F250-00",
    "question": "What is its maximum temperature?",
    "role": "operator",
    "tenant": "north-yard",
    "asset": "F-250",
    "manual": {
      "id": "manual-F-250-r3",
      "source": "manual",
      "text": "Equipment manual for F-250 (revision r3). Maximum operating temperature: 101 C. Known fault: filter blockage. The supporting system is S-650. Maintenance owner: controls.",
      "tenant": "north-yard",
      "family": "F250"
    },
    "current": {
      "revision": "r3",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "101",
        "evidence": [
          "manual-F-250-r3"
        ]
      }
    },
    "stale": {
      "revision": "r2",
      "route": "clarify",
      "expected": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      }
    }
  },
  "decisions": [
    {
      "case_id": "F210-00",
      "family": "F210",
      "slice": "numeric",
      "question": "When was P-210 last inspected?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Shared structured routes",
      "expected_route": "SQL",
      "route": "SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-07-22",
        "evidence": [
          "inventory-P-210-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-07-22",
        "evidence": [
          "inventory-P-210-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "P-210",
            "tenant": "north-yard",
            "inspection": "2025-07-22",
            "version": "r3"
          },
          "evidence": "inventory-P-210-r3"
        }
      }
    },
    {
      "case_id": "F210-03",
      "family": "F210",
      "slice": "numeric",
      "question": "Shift note. Give the last inspection date for P-210.",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Shared structured routes",
      "expected_route": "SQL",
      "route": "SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-07-22",
        "evidence": [
          "inventory-P-210-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-07-22",
        "evidence": [
          "inventory-P-210-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "P-210",
            "tenant": "north-yard",
            "inspection": "2025-07-22",
            "version": "r3"
          },
          "evidence": "inventory-P-210-r3"
        }
      }
    },
    {
      "case_id": "F211-00",
      "family": "F211",
      "slice": "numeric",
      "question": "When was F-211 last inspected?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Shared structured routes",
      "expected_route": "SQL",
      "route": "SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-08-23",
        "evidence": [
          "inventory-F-211-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-08-23",
        "evidence": [
          "inventory-F-211-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "F-211",
            "tenant": "south-yard",
            "inspection": "2025-08-23",
            "version": "r3"
          },
          "evidence": "inventory-F-211-r3"
        }
      }
    },
    {
      "case_id": "F211-03",
      "family": "F211",
      "slice": "numeric",
      "question": "Shift note. Give the last inspection date for F-211.",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Shared structured routes",
      "expected_route": "SQL",
      "route": "SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-08-23",
        "evidence": [
          "inventory-F-211-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-08-23",
        "evidence": [
          "inventory-F-211-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "F-211",
            "tenant": "south-yard",
            "inspection": "2025-08-23",
            "version": "r3"
          },
          "evidence": "inventory-F-211-r3"
        }
      }
    },
    {
      "case_id": "F220-00",
      "family": "F220",
      "slice": "multi_source",
      "question": "Give the last inspection date and supporting system for F-220.",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Shared structured routes",
      "expected_route": "graph + SQL",
      "route": "graph + SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-05-05 | S-620",
        "evidence": [
          "inventory-F-220-r3",
          "graph-F-220-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-05-05 | S-620",
        "evidence": [
          "inventory-F-220-r3",
          "graph-F-220-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "F-220",
            "tenant": "north-yard",
            "inspection": "2025-05-05",
            "version": "r3"
          },
          "evidence": "inventory-F-220-r3"
        },
        "graph": {
          "target": "S-620",
          "type": "supported_by",
          "evidence": "graph-F-220-r3"
        }
      }
    },
    {
      "case_id": "F220-03",
      "family": "F220",
      "slice": "multi_source",
      "question": "Shift note. For F-220, which system supports it and when was its most recent inspection?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Shared structured routes",
      "expected_route": "graph + SQL",
      "route": "graph + SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-05-05 | S-620",
        "evidence": [
          "inventory-F-220-r3",
          "graph-F-220-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-05-05 | S-620",
        "evidence": [
          "inventory-F-220-r3",
          "graph-F-220-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "F-220",
            "tenant": "north-yard",
            "inspection": "2025-05-05",
            "version": "r3"
          },
          "evidence": "inventory-F-220-r3"
        },
        "graph": {
          "target": "S-620",
          "type": "supported_by",
          "evidence": "graph-F-220-r3"
        }
      }
    },
    {
      "case_id": "F221-00",
      "family": "F221",
      "slice": "multi_source",
      "question": "Give the last inspection date and supporting system for V-221.",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Shared structured routes",
      "expected_route": "graph + SQL",
      "route": "graph + SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-06-06 | S-621",
        "evidence": [
          "inventory-V-221-r3",
          "graph-V-221-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-06-06 | S-621",
        "evidence": [
          "inventory-V-221-r3",
          "graph-V-221-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "V-221",
            "tenant": "south-yard",
            "inspection": "2025-06-06",
            "version": "r3"
          },
          "evidence": "inventory-V-221-r3"
        },
        "graph": {
          "target": "S-621",
          "type": "supported_by",
          "evidence": "graph-V-221-r3"
        }
      }
    },
    {
      "case_id": "F221-03",
      "family": "F221",
      "slice": "multi_source",
      "question": "Shift note. For V-221, which system supports it and when was its most recent inspection?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Shared structured routes",
      "expected_route": "graph + SQL",
      "route": "graph + SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-06-06 | S-621",
        "evidence": [
          "inventory-V-221-r3",
          "graph-V-221-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-06-06 | S-621",
        "evidence": [
          "inventory-V-221-r3",
          "graph-V-221-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "V-221",
            "tenant": "south-yard",
            "inspection": "2025-06-06",
            "version": "r3"
          },
          "evidence": "inventory-V-221-r3"
        },
        "graph": {
          "target": "S-621",
          "type": "supported_by",
          "evidence": "graph-V-221-r3"
        }
      }
    },
    {
      "case_id": "F230-00",
      "family": "F230",
      "slice": "ambiguity",
      "question": "What is the maximum temperature for that unit?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Shared structured routes",
      "expected_route": "clarify",
      "route": "clarify",
      "expected": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F230-03",
      "family": "F230",
      "slice": "ambiguity",
      "question": "Shift note. When was that pump last inspected?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Shared structured routes",
      "expected_route": "clarify",
      "route": "clarify",
      "expected": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F231-00",
      "family": "F231",
      "slice": "ambiguity",
      "question": "What is the maximum temperature for that unit?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Shared structured routes",
      "expected_route": "clarify",
      "route": "clarify",
      "expected": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F231-03",
      "family": "F231",
      "slice": "ambiguity",
      "question": "Shift note. When was that pump last inspected?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Shared structured routes",
      "expected_route": "clarify",
      "route": "clarify",
      "expected": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F240-00",
      "family": "F240",
      "slice": "boundary",
      "question": "As a guest, show the inventory record for P-240.",
      "role": "guest",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Shared structured routes",
      "expected_route": "deny",
      "route": "deny",
      "expected": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F240-03",
      "family": "F240",
      "slice": "boundary",
      "question": "Shift note. Guest request: give inspection date for P-240.",
      "role": "guest",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Shared structured routes",
      "expected_route": "deny",
      "route": "deny",
      "expected": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F241-00",
      "family": "F241",
      "slice": "boundary",
      "question": "As a guest, show the inventory record for F-241.",
      "role": "guest",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Shared structured routes",
      "expected_route": "deny",
      "route": "deny",
      "expected": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F241-03",
      "family": "F241",
      "slice": "boundary",
      "question": "Shift note. Guest request: give inspection date for F-241.",
      "role": "guest",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Shared structured routes",
      "expected_route": "deny",
      "route": "deny",
      "expected": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F200-00",
      "family": "F200",
      "slice": "manual",
      "question": "What is the maximum temperature for V-200?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Corpus prefix",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "87",
        "evidence": [
          "manual-V-200-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature for V-200 is 87°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-200-r3\",\n    \"manual-P-210-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-2",
      "evidence_tokens": 112,
      "discarded_tokens": 210,
      "support_visible": true,
      "prompt_tokens": 275,
      "output_text_tokens": 62
    },
    {
      "case_id": "F200-03",
      "family": "F200",
      "slice": "manual",
      "question": "Shift note. What's the thermal limit, in C, of V-200?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Corpus prefix",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "87",
        "evidence": [
          "manual-V-200-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The thermal limit for V-200 is not specified.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-200-r3\",\n    \"manual-P-210-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-2",
      "evidence_tokens": 112,
      "discarded_tokens": 210,
      "support_visible": true,
      "prompt_tokens": 282,
      "output_text_tokens": 60
    },
    {
      "case_id": "F201-00",
      "family": "F201",
      "slice": "manual",
      "question": "What is the maximum temperature for P-201?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Corpus prefix",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "70",
        "evidence": [
          "manual-P-201-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature for P-201 is 70°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-P-201-r3\",\n    \"manual-F-211-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-22",
      "evidence_tokens": 112,
      "discarded_tokens": 207,
      "support_visible": true,
      "prompt_tokens": 275,
      "output_text_tokens": 62
    },
    {
      "case_id": "F201-03",
      "family": "F201",
      "slice": "manual",
      "question": "Shift note. What's the thermal limit, in C, of P-201?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Corpus prefix",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "70",
        "evidence": [
          "manual-P-201-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The thermal limit for P-201 is not specified.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-P-201-r3\",\n    \"manual-F-211-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-22",
      "evidence_tokens": 112,
      "discarded_tokens": 207,
      "support_visible": true,
      "prompt_tokens": 282,
      "output_text_tokens": 60
    },
    {
      "case_id": "F200-00",
      "family": "F200",
      "slice": "manual",
      "question": "What is the maximum temperature for V-200?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Exact ID first",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "87",
        "evidence": [
          "manual-V-200-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature for V-200 is 87°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-200-r3\",\n    \"manual-P-210-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-2",
      "evidence_tokens": 112,
      "discarded_tokens": 210,
      "support_visible": true,
      "prompt_tokens": 275,
      "output_text_tokens": 62
    },
    {
      "case_id": "F200-03",
      "family": "F200",
      "slice": "manual",
      "question": "Shift note. What's the thermal limit, in C, of V-200?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Exact ID first",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "87",
        "evidence": [
          "manual-V-200-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The thermal limit for V-200 is not specified.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-200-r3\",\n    \"manual-P-210-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-2",
      "evidence_tokens": 112,
      "discarded_tokens": 210,
      "support_visible": true,
      "prompt_tokens": 282,
      "output_text_tokens": 60
    },
    {
      "case_id": "F201-00",
      "family": "F201",
      "slice": "manual",
      "question": "What is the maximum temperature for P-201?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Exact ID first",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "70",
        "evidence": [
          "manual-P-201-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature for P-201 is 70°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-P-201-r3\",\n    \"manual-F-211-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-22",
      "evidence_tokens": 112,
      "discarded_tokens": 207,
      "support_visible": true,
      "prompt_tokens": 275,
      "output_text_tokens": 62
    },
    {
      "case_id": "F201-03",
      "family": "F201",
      "slice": "manual",
      "question": "Shift note. What's the thermal limit, in C, of P-201?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Exact ID first",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "70",
        "evidence": [
          "manual-P-201-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The thermal limit for P-201 is not specified.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-P-201-r3\",\n    \"manual-F-211-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-22",
      "evidence_tokens": 112,
      "discarded_tokens": 207,
      "support_visible": true,
      "prompt_tokens": 282,
      "output_text_tokens": 60
    },
    {
      "case_id": "F200-00",
      "family": "F200",
      "slice": "manual",
      "question": "What is the maximum temperature for V-200?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "All tenant manuals",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "87",
        "evidence": [
          "manual-V-200-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature for V-200 is 87°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-200-r3\",\n    \"manual-P-210-r3\",\n    \"manual-F-220-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-220-r3] Equipment manual for F-220 (revision r3). Maximum operating temperature: 71 C. Known fault: seal wear. The supporting system is S-620. Maintenance owner: controls.\n[manual-V-230-r3] Equipment manual for V-230 (revision r3). Maximum operating temperature: 81 C. Known fault: filter blockage. The supporting system is S-630. Maintenance owner: electrical.\n[manual-P-240-r3] Equipment manual for P-240 (revision r3). Maximum operating temperature: 91 C. Known fault: seal wear. The supporting system is S-640. Maintenance owner: mechanical.\n[manual-F-250-r3] Equipment manual for F-250 (revision r3). Maximum operating temperature: 101 C. Known fault: filter blockage. The supporting system is S-650. Maintenance owner: controls.",
      "evidence_tokens": 322,
      "discarded_tokens": 0,
      "support_visible": true,
      "prompt_tokens": 485,
      "output_text_tokens": 73
    },
    {
      "case_id": "F200-03",
      "family": "F200",
      "slice": "manual",
      "question": "Shift note. What's the thermal limit, in C, of V-200?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "All tenant manuals",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "87",
        "evidence": [
          "manual-V-200-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The thermal limit for V-200 is not specified.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-200-r3\",\n    \"manual-P-210-r3\",\n    \"manual-F-220-r3\",\n    \"manual-V-230-r3\",\n    \"manual-P-240-r3\",\n    \"manual-F-250-r3\"\n",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-220-r3] Equipment manual for F-220 (revision r3). Maximum operating temperature: 71 C. Known fault: seal wear. The supporting system is S-620. Maintenance owner: controls.\n[manual-V-230-r3] Equipment manual for V-230 (revision r3). Maximum operating temperature: 81 C. Known fault: filter blockage. The supporting system is S-630. Maintenance owner: electrical.\n[manual-P-240-r3] Equipment manual for P-240 (revision r3). Maximum operating temperature: 91 C. Known fault: seal wear. The supporting system is S-640. Maintenance owner: mechanical.\n[manual-F-250-r3] Equipment manual for F-250 (revision r3). Maximum operating temperature: 101 C. Known fault: filter blockage. The supporting system is S-650. Maintenance owner: controls.",
      "evidence_tokens": 322,
      "discarded_tokens": 0,
      "support_visible": true,
      "prompt_tokens": 492,
      "output_text_tokens": 100
    },
    {
      "case_id": "F201-00",
      "family": "F201",
      "slice": "manual",
      "question": "What is the maximum temperature for P-201?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "All tenant manuals",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "70",
        "evidence": [
          "manual-P-201-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature for P-201 is 70°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-P-201-r3\",\n    \"manual-F-211-r3\",\n    \"manual-V-221-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-221-r3] Equipment manual for V-221 (revision r3). Maximum operating temperature: 90 C. Known fault: sensor drift. The supporting system is S-621. Maintenance owner: electrical.\n[manual-P-231-r3] Equipment manual for P-231 (revision r3). Maximum operating temperature: 100 C. Known fault: bearing vibration. The supporting system is S-631. Maintenance owner: mechanical.\n[manual-F-241-r3] Equipment manual for F-241 (revision r3). Maximum operating temperature: 74 C. Known fault: sensor drift. The supporting system is S-641. Maintenance owner: controls.\n[manual-V-251-r3] Equipment manual for V-251 (revision r3). Maximum operating temperature: 84 C. Known fault: bearing vibration. The supporting system is S-651. Maintenance owner: electrical.",
      "evidence_tokens": 319,
      "discarded_tokens": 0,
      "support_visible": true,
      "prompt_tokens": 482,
      "output_text_tokens": 73
    },
    {
      "case_id": "F201-03",
      "family": "F201",
      "slice": "manual",
      "question": "Shift note. What's the thermal limit, in C, of P-201?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "All tenant manuals",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "70",
        "evidence": [
          "manual-P-201-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The thermal limit for P-201 is not specified.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-P-201-r3\",\n    \"manual-F-211-r3\",\n    \"manual-V-221-r3\",\n    \"manual-P-231-r3\",\n    \"manual-F-241-r3\",\n    \"manual-V-251-r3\"\n",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-221-r3] Equipment manual for V-221 (revision r3). Maximum operating temperature: 90 C. Known fault: sensor drift. The supporting system is S-621. Maintenance owner: electrical.\n[manual-P-231-r3] Equipment manual for P-231 (revision r3). Maximum operating temperature: 100 C. Known fault: bearing vibration. The supporting system is S-631. Maintenance owner: mechanical.\n[manual-F-241-r3] Equipment manual for F-241 (revision r3). Maximum operating temperature: 74 C. Known fault: sensor drift. The supporting system is S-641. Maintenance owner: controls.\n[manual-V-251-r3] Equipment manual for V-251 (revision r3). Maximum operating temperature: 84 C. Known fault: bearing vibration. The supporting system is S-651. Maintenance owner: electrical.",
      "evidence_tokens": 319,
      "discarded_tokens": 0,
      "support_visible": true,
      "prompt_tokens": 489,
      "output_text_tokens": 100
    },
    {
      "case_id": "F250-00",
      "family": "F250",
      "slice": "follow_up",
      "question": "What is its maximum temperature?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "F-250",
      "previous_version": "r3",
      "method": "All tenant manuals",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "101",
        "evidence": [
          "manual-F-250-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature of F-250 is 101 C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-F-250-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-220-r3] Equipment manual for F-220 (revision r3). Maximum operating temperature: 71 C. Known fault: seal wear. The supporting system is S-620. Maintenance owner: controls.\n[manual-V-230-r3] Equipment manual for V-230 (revision r3). Maximum operating temperature: 81 C. Known fault: filter blockage. The supporting system is S-630. Maintenance owner: electrical.\n[manual-P-240-r3] Equipment manual for P-240 (revision r3). Maximum operating temperature: 91 C. Known fault: seal wear. The supporting system is S-640. Maintenance owner: mechanical.\n[manual-F-250-r3] Equipment manual for F-250 (revision r3). Maximum operating temperature: 101 C. Known fault: filter blockage. The supporting system is S-650. Maintenance owner: controls.",
      "evidence_tokens": 322,
      "discarded_tokens": 0,
      "support_visible": true,
      "prompt_tokens": 483,
      "output_text_tokens": 52
    },
    {
      "case_id": "F250-03",
      "family": "F250",
      "slice": "follow_up",
      "question": "Shift note. And how hot can this one run?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "F-250",
      "previous_version": "r3",
      "method": "All tenant manuals",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "101",
        "evidence": [
          "manual-F-250-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum operating temperature of the F-250 equipment is 101°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-F-250-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-220-r3] Equipment manual for F-220 (revision r3). Maximum operating temperature: 71 C. Known fault: seal wear. The supporting system is S-620. Maintenance owner: controls.\n[manual-V-230-r3] Equipment manual for V-230 (revision r3). Maximum operating temperature: 81 C. Known fault: filter blockage. The supporting system is S-630. Maintenance owner: electrical.\n[manual-P-240-r3] Equipment manual for P-240 (revision r3). Maximum operating temperature: 91 C. Known fault: seal wear. The supporting system is S-640. Maintenance owner: mechanical.\n[manual-F-250-r3] Equipment manual for F-250 (revision r3). Maximum operating temperature: 101 C. Known fault: filter blockage. The supporting system is S-650. Maintenance owner: controls.",
      "evidence_tokens": 322,
      "discarded_tokens": 0,
      "support_visible": true,
      "prompt_tokens": 488,
      "output_text_tokens": 55
    },
    {
      "case_id": "F251-00",
      "family": "F251",
      "slice": "follow_up",
      "question": "What is its maximum temperature?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "V-251",
      "previous_version": "r3",
      "method": "All tenant manuals",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "84",
        "evidence": [
          "manual-V-251-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature of V-251 is 84°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-251-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-221-r3] Equipment manual for V-221 (revision r3). Maximum operating temperature: 90 C. Known fault: sensor drift. The supporting system is S-621. Maintenance owner: electrical.\n[manual-P-231-r3] Equipment manual for P-231 (revision r3). Maximum operating temperature: 100 C. Known fault: bearing vibration. The supporting system is S-631. Maintenance owner: mechanical.\n[manual-F-241-r3] Equipment manual for F-241 (revision r3). Maximum operating temperature: 74 C. Known fault: sensor drift. The supporting system is S-641. Maintenance owner: controls.\n[manual-V-251-r3] Equipment manual for V-251 (revision r3). Maximum operating temperature: 84 C. Known fault: bearing vibration. The supporting system is S-651. Maintenance owner: electrical.",
      "evidence_tokens": 319,
      "discarded_tokens": 0,
      "support_visible": true,
      "prompt_tokens": 480,
      "output_text_tokens": 51
    },
    {
      "case_id": "F251-03",
      "family": "F251",
      "slice": "follow_up",
      "question": "Shift note. And how hot can this one run?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "V-251",
      "previous_version": "r3",
      "method": "All tenant manuals",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "84",
        "evidence": [
          "manual-V-251-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum operating temperature of V-251 is 84°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-251-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-221-r3] Equipment manual for V-221 (revision r3). Maximum operating temperature: 90 C. Known fault: sensor drift. The supporting system is S-621. Maintenance owner: electrical.\n[manual-P-231-r3] Equipment manual for P-231 (revision r3). Maximum operating temperature: 100 C. Known fault: bearing vibration. The supporting system is S-631. Maintenance owner: mechanical.\n[manual-F-241-r3] Equipment manual for F-241 (revision r3). Maximum operating temperature: 74 C. Known fault: sensor drift. The supporting system is S-641. Maintenance owner: controls.\n[manual-V-251-r3] Equipment manual for V-251 (revision r3). Maximum operating temperature: 84 C. Known fault: bearing vibration. The supporting system is S-651. Maintenance owner: electrical.",
      "evidence_tokens": 319,
      "discarded_tokens": 0,
      "support_visible": true,
      "prompt_tokens": 485,
      "output_text_tokens": 52
    },
    {
      "case_id": "F250-00",
      "family": "F250",
      "slice": "follow_up",
      "question": "What is its maximum temperature?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "F-250",
      "previous_version": "r3",
      "method": "Exact ID first",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "101",
        "evidence": [
          "manual-F-250-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature of F-250 is 101°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-F-250-r3\",\n    \"DATE | SYSTEM\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-F-250-r3] Equipment manual for F-250 (revision r3). Maximum operating temperature: 101 C. Known fault: filter blockage. The supporting system is S-650. Maintenance owner: controls.\n[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-",
      "evidence_tokens": 112,
      "discarded_tokens": 210,
      "support_visible": true,
      "prompt_tokens": 273,
      "output_text_tokens": 58
    },
    {
      "case_id": "F250-03",
      "family": "F250",
      "slice": "follow_up",
      "question": "Shift note. And how hot can this one run?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "F-250",
      "previous_version": "r3",
      "method": "Exact ID first",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "101",
        "evidence": [
          "manual-F-250-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum operating temperature of the F-250 is 101°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-F-250-r3\",\n    \"manual-V-200-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-F-250-r3] Equipment manual for F-250 (revision r3). Maximum operating temperature: 101 C. Known fault: filter blockage. The supporting system is S-650. Maintenance owner: controls.\n[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-",
      "evidence_tokens": 112,
      "discarded_tokens": 210,
      "support_visible": true,
      "prompt_tokens": 278,
      "output_text_tokens": 65
    },
    {
      "case_id": "F251-00",
      "family": "F251",
      "slice": "follow_up",
      "question": "What is its maximum temperature?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "V-251",
      "previous_version": "r3",
      "method": "Exact ID first",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "84",
        "evidence": [
          "manual-V-251-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature of V-251 is 84°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-251-r3\",\n    \"manual-P-201-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-251-r3] Equipment manual for V-251 (revision r3). Maximum operating temperature: 84 C. Known fault: bearing vibration. The supporting system is S-651. Maintenance owner: electrical.\n[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-21",
      "evidence_tokens": 112,
      "discarded_tokens": 207,
      "support_visible": true,
      "prompt_tokens": 273,
      "output_text_tokens": 62
    },
    {
      "case_id": "F251-03",
      "family": "F251",
      "slice": "follow_up",
      "question": "Shift note. And how hot can this one run?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "V-251",
      "previous_version": "r3",
      "method": "Exact ID first",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "84",
        "evidence": [
          "manual-V-251-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum operating temperature of V-251 is 84°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-251-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-251-r3] Equipment manual for V-251 (revision r3). Maximum operating temperature: 84 C. Known fault: bearing vibration. The supporting system is S-651. Maintenance owner: electrical.\n[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-21",
      "evidence_tokens": 112,
      "discarded_tokens": 207,
      "support_visible": true,
      "prompt_tokens": 278,
      "output_text_tokens": 52
    },
    {
      "case_id": "F250-00",
      "family": "F250",
      "slice": "follow_up",
      "question": "What is its maximum temperature?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "F-250",
      "previous_version": "r3",
      "method": "Corpus prefix",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "101",
        "evidence": [
          "manual-F-250-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature of F-250 cannot be determined directly from the provided information.\",\n  \"value\": \"\",\n  \"evidence\": []\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-2",
      "evidence_tokens": 112,
      "discarded_tokens": 210,
      "support_visible": false,
      "prompt_tokens": 273,
      "output_text_tokens": 40
    },
    {
      "case_id": "F250-03",
      "family": "F250",
      "slice": "follow_up",
      "question": "Shift note. And how hot can this one run?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "F-250",
      "previous_version": "r3",
      "method": "Corpus prefix",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "101",
        "evidence": [
          "manual-F-250-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum operating temperature of the F-250 is not specified.\",\n  \"value\": \"\",\n  \"evidence\": []\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-2",
      "evidence_tokens": 112,
      "discarded_tokens": 210,
      "support_visible": false,
      "prompt_tokens": 278,
      "output_text_tokens": 37
    },
    {
      "case_id": "F251-00",
      "family": "F251",
      "slice": "follow_up",
      "question": "What is its maximum temperature?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "V-251",
      "previous_version": "r3",
      "method": "Corpus prefix",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "84",
        "evidence": [
          "manual-V-251-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature of V-251 cannot be determined directly from the provided information.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-P-201-r3\",\n    \"manual-F-211-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-22",
      "evidence_tokens": 112,
      "discarded_tokens": 207,
      "support_visible": false,
      "prompt_tokens": 273,
      "output_text_tokens": 65
    },
    {
      "case_id": "F251-03",
      "family": "F251",
      "slice": "follow_up",
      "question": "Shift note. And how hot can this one run?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "V-251",
      "previous_version": "r3",
      "method": "Corpus prefix",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "84",
        "evidence": [
          "manual-V-251-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum operating temperature of V-251 is not specified.\",\n  \"value\": \"\",\n  \"evidence\": []\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-22",
      "evidence_tokens": 112,
      "discarded_tokens": 207,
      "support_visible": false,
      "prompt_tokens": 278,
      "output_text_tokens": 36
    },
    {
      "case_id": "F210-00",
      "family": "F210",
      "slice": "numeric",
      "question": "When was P-210 last inspected?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "SQL",
      "route": "SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-07-22",
        "evidence": [
          "inventory-P-210-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-07-22",
        "evidence": [
          "inventory-P-210-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "P-210",
            "tenant": "north-yard",
            "inspection": "2025-07-22",
            "version": "r3"
          },
          "evidence": "inventory-P-210-r3"
        }
      }
    },
    {
      "case_id": "F210-03",
      "family": "F210",
      "slice": "numeric",
      "question": "Shift note. Give the last inspection date for P-210.",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "SQL",
      "route": "SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-07-22",
        "evidence": [
          "inventory-P-210-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-07-22",
        "evidence": [
          "inventory-P-210-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "P-210",
            "tenant": "north-yard",
            "inspection": "2025-07-22",
            "version": "r3"
          },
          "evidence": "inventory-P-210-r3"
        }
      }
    },
    {
      "case_id": "F211-00",
      "family": "F211",
      "slice": "numeric",
      "question": "When was F-211 last inspected?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "SQL",
      "route": "SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-08-23",
        "evidence": [
          "inventory-F-211-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-08-23",
        "evidence": [
          "inventory-F-211-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "F-211",
            "tenant": "south-yard",
            "inspection": "2025-08-23",
            "version": "r3"
          },
          "evidence": "inventory-F-211-r3"
        }
      }
    },
    {
      "case_id": "F211-03",
      "family": "F211",
      "slice": "numeric",
      "question": "Shift note. Give the last inspection date for F-211.",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "SQL",
      "route": "SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-08-23",
        "evidence": [
          "inventory-F-211-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-08-23",
        "evidence": [
          "inventory-F-211-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "F-211",
            "tenant": "south-yard",
            "inspection": "2025-08-23",
            "version": "r3"
          },
          "evidence": "inventory-F-211-r3"
        }
      }
    },
    {
      "case_id": "F220-00",
      "family": "F220",
      "slice": "multi_source",
      "question": "Give the last inspection date and supporting system for F-220.",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "graph + SQL",
      "route": "graph + SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-05-05 | S-620",
        "evidence": [
          "inventory-F-220-r3",
          "graph-F-220-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-05-05 | S-620",
        "evidence": [
          "inventory-F-220-r3",
          "graph-F-220-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "F-220",
            "tenant": "north-yard",
            "inspection": "2025-05-05",
            "version": "r3"
          },
          "evidence": "inventory-F-220-r3"
        },
        "graph": {
          "target": "S-620",
          "type": "supported_by",
          "evidence": "graph-F-220-r3"
        }
      }
    },
    {
      "case_id": "F220-03",
      "family": "F220",
      "slice": "multi_source",
      "question": "Shift note. For F-220, which system supports it and when was its most recent inspection?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "graph + SQL",
      "route": "graph + SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-05-05 | S-620",
        "evidence": [
          "inventory-F-220-r3",
          "graph-F-220-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-05-05 | S-620",
        "evidence": [
          "inventory-F-220-r3",
          "graph-F-220-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "F-220",
            "tenant": "north-yard",
            "inspection": "2025-05-05",
            "version": "r3"
          },
          "evidence": "inventory-F-220-r3"
        },
        "graph": {
          "target": "S-620",
          "type": "supported_by",
          "evidence": "graph-F-220-r3"
        }
      }
    },
    {
      "case_id": "F221-00",
      "family": "F221",
      "slice": "multi_source",
      "question": "Give the last inspection date and supporting system for V-221.",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "graph + SQL",
      "route": "graph + SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-06-06 | S-621",
        "evidence": [
          "inventory-V-221-r3",
          "graph-V-221-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-06-06 | S-621",
        "evidence": [
          "inventory-V-221-r3",
          "graph-V-221-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "V-221",
            "tenant": "south-yard",
            "inspection": "2025-06-06",
            "version": "r3"
          },
          "evidence": "inventory-V-221-r3"
        },
        "graph": {
          "target": "S-621",
          "type": "supported_by",
          "evidence": "graph-V-221-r3"
        }
      }
    },
    {
      "case_id": "F221-03",
      "family": "F221",
      "slice": "multi_source",
      "question": "Shift note. For V-221, which system supports it and when was its most recent inspection?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "graph + SQL",
      "route": "graph + SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-06-06 | S-621",
        "evidence": [
          "inventory-V-221-r3",
          "graph-V-221-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-06-06 | S-621",
        "evidence": [
          "inventory-V-221-r3",
          "graph-V-221-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "V-221",
            "tenant": "south-yard",
            "inspection": "2025-06-06",
            "version": "r3"
          },
          "evidence": "inventory-V-221-r3"
        },
        "graph": {
          "target": "S-621",
          "type": "supported_by",
          "evidence": "graph-V-221-r3"
        }
      }
    },
    {
      "case_id": "F230-00",
      "family": "F230",
      "slice": "ambiguity",
      "question": "What is the maximum temperature for that unit?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "clarify",
      "route": "clarify",
      "expected": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F230-03",
      "family": "F230",
      "slice": "ambiguity",
      "question": "Shift note. When was that pump last inspected?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "clarify",
      "route": "clarify",
      "expected": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F231-00",
      "family": "F231",
      "slice": "ambiguity",
      "question": "What is the maximum temperature for that unit?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "clarify",
      "route": "clarify",
      "expected": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F231-03",
      "family": "F231",
      "slice": "ambiguity",
      "question": "Shift note. When was that pump last inspected?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "clarify",
      "route": "clarify",
      "expected": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F240-00",
      "family": "F240",
      "slice": "boundary",
      "question": "As a guest, show the inventory record for P-240.",
      "role": "guest",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "deny",
      "route": "deny",
      "expected": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F240-03",
      "family": "F240",
      "slice": "boundary",
      "question": "Shift note. Guest request: give inspection date for P-240.",
      "role": "guest",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "deny",
      "route": "deny",
      "expected": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F241-00",
      "family": "F241",
      "slice": "boundary",
      "question": "As a guest, show the inventory record for F-241.",
      "role": "guest",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "deny",
      "route": "deny",
      "expected": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F241-03",
      "family": "F241",
      "slice": "boundary",
      "question": "Shift note. Guest request: give inspection date for F-241.",
      "role": "guest",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "deny",
      "route": "deny",
      "expected": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F200-00",
      "family": "F200",
      "slice": "manual",
      "question": "What is the maximum temperature for V-200?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "87",
        "evidence": [
          "manual-V-200-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature for V-200 is 87°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-200-r3\",\n    \"manual-P-210-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-2",
      "evidence_tokens": 112,
      "discarded_tokens": 210,
      "support_visible": true,
      "prompt_tokens": 275,
      "output_text_tokens": 62
    },
    {
      "case_id": "F200-03",
      "family": "F200",
      "slice": "manual",
      "question": "Shift note. What's the thermal limit, in C, of V-200?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "87",
        "evidence": [
          "manual-V-200-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The thermal limit for V-200 is not specified.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-200-r3\",\n    \"manual-P-210-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-2",
      "evidence_tokens": 112,
      "discarded_tokens": 210,
      "support_visible": true,
      "prompt_tokens": 282,
      "output_text_tokens": 60
    },
    {
      "case_id": "F201-00",
      "family": "F201",
      "slice": "manual",
      "question": "What is the maximum temperature for P-201?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "70",
        "evidence": [
          "manual-P-201-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature for P-201 is 70°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-P-201-r3\",\n    \"manual-F-211-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-22",
      "evidence_tokens": 112,
      "discarded_tokens": 207,
      "support_visible": true,
      "prompt_tokens": 275,
      "output_text_tokens": 62
    },
    {
      "case_id": "F201-03",
      "family": "F201",
      "slice": "manual",
      "question": "Shift note. What's the thermal limit, in C, of P-201?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · corpus prefix",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "70",
        "evidence": [
          "manual-P-201-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The thermal limit for P-201 is not specified.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-P-201-r3\",\n    \"manual-F-211-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-22",
      "evidence_tokens": 112,
      "discarded_tokens": 207,
      "support_visible": true,
      "prompt_tokens": 282,
      "output_text_tokens": 60
    },
    {
      "case_id": "F250-00",
      "family": "F250",
      "slice": "follow_up",
      "question": "What is its maximum temperature?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "F-250",
      "previous_version": "r3",
      "method": "Routed · corpus prefix",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "101",
        "evidence": [
          "manual-F-250-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature of F-250 cannot be determined directly from the provided information.\",\n  \"value\": \"\",\n  \"evidence\": []\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-2",
      "evidence_tokens": 112,
      "discarded_tokens": 210,
      "support_visible": false,
      "prompt_tokens": 273,
      "output_text_tokens": 40
    },
    {
      "case_id": "F250-03",
      "family": "F250",
      "slice": "follow_up",
      "question": "Shift note. And how hot can this one run?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "F-250",
      "previous_version": "r3",
      "method": "Routed · corpus prefix",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "101",
        "evidence": [
          "manual-F-250-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum operating temperature of the F-250 is not specified.\",\n  \"value\": \"\",\n  \"evidence\": []\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-2",
      "evidence_tokens": 112,
      "discarded_tokens": 210,
      "support_visible": false,
      "prompt_tokens": 278,
      "output_text_tokens": 37
    },
    {
      "case_id": "F251-00",
      "family": "F251",
      "slice": "follow_up",
      "question": "What is its maximum temperature?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "V-251",
      "previous_version": "r3",
      "method": "Routed · corpus prefix",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "84",
        "evidence": [
          "manual-V-251-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature of V-251 cannot be determined directly from the provided information.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-P-201-r3\",\n    \"manual-F-211-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-22",
      "evidence_tokens": 112,
      "discarded_tokens": 207,
      "support_visible": false,
      "prompt_tokens": 273,
      "output_text_tokens": 65
    },
    {
      "case_id": "F251-03",
      "family": "F251",
      "slice": "follow_up",
      "question": "Shift note. And how hot can this one run?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "V-251",
      "previous_version": "r3",
      "method": "Routed · corpus prefix",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "84",
        "evidence": [
          "manual-V-251-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum operating temperature of V-251 is not specified.\",\n  \"value\": \"\",\n  \"evidence\": []\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-22",
      "evidence_tokens": 112,
      "discarded_tokens": 207,
      "support_visible": false,
      "prompt_tokens": 278,
      "output_text_tokens": 36
    },
    {
      "case_id": "F210-00",
      "family": "F210",
      "slice": "numeric",
      "question": "When was P-210 last inspected?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "SQL",
      "route": "SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-07-22",
        "evidence": [
          "inventory-P-210-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-07-22",
        "evidence": [
          "inventory-P-210-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "P-210",
            "tenant": "north-yard",
            "inspection": "2025-07-22",
            "version": "r3"
          },
          "evidence": "inventory-P-210-r3"
        }
      }
    },
    {
      "case_id": "F210-03",
      "family": "F210",
      "slice": "numeric",
      "question": "Shift note. Give the last inspection date for P-210.",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "SQL",
      "route": "SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-07-22",
        "evidence": [
          "inventory-P-210-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-07-22",
        "evidence": [
          "inventory-P-210-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "P-210",
            "tenant": "north-yard",
            "inspection": "2025-07-22",
            "version": "r3"
          },
          "evidence": "inventory-P-210-r3"
        }
      }
    },
    {
      "case_id": "F211-00",
      "family": "F211",
      "slice": "numeric",
      "question": "When was F-211 last inspected?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "SQL",
      "route": "SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-08-23",
        "evidence": [
          "inventory-F-211-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-08-23",
        "evidence": [
          "inventory-F-211-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "F-211",
            "tenant": "south-yard",
            "inspection": "2025-08-23",
            "version": "r3"
          },
          "evidence": "inventory-F-211-r3"
        }
      }
    },
    {
      "case_id": "F211-03",
      "family": "F211",
      "slice": "numeric",
      "question": "Shift note. Give the last inspection date for F-211.",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "SQL",
      "route": "SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-08-23",
        "evidence": [
          "inventory-F-211-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-08-23",
        "evidence": [
          "inventory-F-211-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "F-211",
            "tenant": "south-yard",
            "inspection": "2025-08-23",
            "version": "r3"
          },
          "evidence": "inventory-F-211-r3"
        }
      }
    },
    {
      "case_id": "F220-00",
      "family": "F220",
      "slice": "multi_source",
      "question": "Give the last inspection date and supporting system for F-220.",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "graph + SQL",
      "route": "graph + SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-05-05 | S-620",
        "evidence": [
          "inventory-F-220-r3",
          "graph-F-220-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-05-05 | S-620",
        "evidence": [
          "inventory-F-220-r3",
          "graph-F-220-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "F-220",
            "tenant": "north-yard",
            "inspection": "2025-05-05",
            "version": "r3"
          },
          "evidence": "inventory-F-220-r3"
        },
        "graph": {
          "target": "S-620",
          "type": "supported_by",
          "evidence": "graph-F-220-r3"
        }
      }
    },
    {
      "case_id": "F220-03",
      "family": "F220",
      "slice": "multi_source",
      "question": "Shift note. For F-220, which system supports it and when was its most recent inspection?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "graph + SQL",
      "route": "graph + SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-05-05 | S-620",
        "evidence": [
          "inventory-F-220-r3",
          "graph-F-220-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-05-05 | S-620",
        "evidence": [
          "inventory-F-220-r3",
          "graph-F-220-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "F-220",
            "tenant": "north-yard",
            "inspection": "2025-05-05",
            "version": "r3"
          },
          "evidence": "inventory-F-220-r3"
        },
        "graph": {
          "target": "S-620",
          "type": "supported_by",
          "evidence": "graph-F-220-r3"
        }
      }
    },
    {
      "case_id": "F221-00",
      "family": "F221",
      "slice": "multi_source",
      "question": "Give the last inspection date and supporting system for V-221.",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "graph + SQL",
      "route": "graph + SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-06-06 | S-621",
        "evidence": [
          "inventory-V-221-r3",
          "graph-V-221-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-06-06 | S-621",
        "evidence": [
          "inventory-V-221-r3",
          "graph-V-221-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "V-221",
            "tenant": "south-yard",
            "inspection": "2025-06-06",
            "version": "r3"
          },
          "evidence": "inventory-V-221-r3"
        },
        "graph": {
          "target": "S-621",
          "type": "supported_by",
          "evidence": "graph-V-221-r3"
        }
      }
    },
    {
      "case_id": "F221-03",
      "family": "F221",
      "slice": "multi_source",
      "question": "Shift note. For V-221, which system supports it and when was its most recent inspection?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "graph + SQL",
      "route": "graph + SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-06-06 | S-621",
        "evidence": [
          "inventory-V-221-r3",
          "graph-V-221-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-06-06 | S-621",
        "evidence": [
          "inventory-V-221-r3",
          "graph-V-221-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "V-221",
            "tenant": "south-yard",
            "inspection": "2025-06-06",
            "version": "r3"
          },
          "evidence": "inventory-V-221-r3"
        },
        "graph": {
          "target": "S-621",
          "type": "supported_by",
          "evidence": "graph-V-221-r3"
        }
      }
    },
    {
      "case_id": "F230-00",
      "family": "F230",
      "slice": "ambiguity",
      "question": "What is the maximum temperature for that unit?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "clarify",
      "route": "clarify",
      "expected": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F230-03",
      "family": "F230",
      "slice": "ambiguity",
      "question": "Shift note. When was that pump last inspected?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "clarify",
      "route": "clarify",
      "expected": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F231-00",
      "family": "F231",
      "slice": "ambiguity",
      "question": "What is the maximum temperature for that unit?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "clarify",
      "route": "clarify",
      "expected": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F231-03",
      "family": "F231",
      "slice": "ambiguity",
      "question": "Shift note. When was that pump last inspected?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "clarify",
      "route": "clarify",
      "expected": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F240-00",
      "family": "F240",
      "slice": "boundary",
      "question": "As a guest, show the inventory record for P-240.",
      "role": "guest",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "deny",
      "route": "deny",
      "expected": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F240-03",
      "family": "F240",
      "slice": "boundary",
      "question": "Shift note. Guest request: give inspection date for P-240.",
      "role": "guest",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "deny",
      "route": "deny",
      "expected": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F241-00",
      "family": "F241",
      "slice": "boundary",
      "question": "As a guest, show the inventory record for F-241.",
      "role": "guest",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "deny",
      "route": "deny",
      "expected": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F241-03",
      "family": "F241",
      "slice": "boundary",
      "question": "Shift note. Guest request: give inspection date for F-241.",
      "role": "guest",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "deny",
      "route": "deny",
      "expected": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F200-00",
      "family": "F200",
      "slice": "manual",
      "question": "What is the maximum temperature for V-200?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "87",
        "evidence": [
          "manual-V-200-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature for V-200 is 87°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-200-r3\",\n    \"manual-P-210-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-2",
      "evidence_tokens": 112,
      "discarded_tokens": 210,
      "support_visible": true,
      "prompt_tokens": 275,
      "output_text_tokens": 62
    },
    {
      "case_id": "F200-03",
      "family": "F200",
      "slice": "manual",
      "question": "Shift note. What's the thermal limit, in C, of V-200?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "87",
        "evidence": [
          "manual-V-200-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The thermal limit for V-200 is not specified.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-200-r3\",\n    \"manual-P-210-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-2",
      "evidence_tokens": 112,
      "discarded_tokens": 210,
      "support_visible": true,
      "prompt_tokens": 282,
      "output_text_tokens": 60
    },
    {
      "case_id": "F201-00",
      "family": "F201",
      "slice": "manual",
      "question": "What is the maximum temperature for P-201?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "70",
        "evidence": [
          "manual-P-201-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature for P-201 is 70°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-P-201-r3\",\n    \"manual-F-211-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-22",
      "evidence_tokens": 112,
      "discarded_tokens": 207,
      "support_visible": true,
      "prompt_tokens": 275,
      "output_text_tokens": 62
    },
    {
      "case_id": "F201-03",
      "family": "F201",
      "slice": "manual",
      "question": "Shift note. What's the thermal limit, in C, of P-201?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · exact ID first",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "70",
        "evidence": [
          "manual-P-201-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The thermal limit for P-201 is not specified.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-P-201-r3\",\n    \"manual-F-211-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-22",
      "evidence_tokens": 112,
      "discarded_tokens": 207,
      "support_visible": true,
      "prompt_tokens": 282,
      "output_text_tokens": 60
    },
    {
      "case_id": "F250-00",
      "family": "F250",
      "slice": "follow_up",
      "question": "What is its maximum temperature?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "F-250",
      "previous_version": "r3",
      "method": "Routed · exact ID first",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "101",
        "evidence": [
          "manual-F-250-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature of F-250 is 101°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-F-250-r3\",\n    \"DATE | SYSTEM\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-F-250-r3] Equipment manual for F-250 (revision r3). Maximum operating temperature: 101 C. Known fault: filter blockage. The supporting system is S-650. Maintenance owner: controls.\n[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-",
      "evidence_tokens": 112,
      "discarded_tokens": 210,
      "support_visible": true,
      "prompt_tokens": 273,
      "output_text_tokens": 58
    },
    {
      "case_id": "F250-03",
      "family": "F250",
      "slice": "follow_up",
      "question": "Shift note. And how hot can this one run?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "F-250",
      "previous_version": "r3",
      "method": "Routed · exact ID first",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "101",
        "evidence": [
          "manual-F-250-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum operating temperature of the F-250 is 101°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-F-250-r3\",\n    \"manual-V-200-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-F-250-r3] Equipment manual for F-250 (revision r3). Maximum operating temperature: 101 C. Known fault: filter blockage. The supporting system is S-650. Maintenance owner: controls.\n[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-",
      "evidence_tokens": 112,
      "discarded_tokens": 210,
      "support_visible": true,
      "prompt_tokens": 278,
      "output_text_tokens": 65
    },
    {
      "case_id": "F251-00",
      "family": "F251",
      "slice": "follow_up",
      "question": "What is its maximum temperature?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "V-251",
      "previous_version": "r3",
      "method": "Routed · exact ID first",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "84",
        "evidence": [
          "manual-V-251-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature of V-251 is 84°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-251-r3\",\n    \"manual-P-201-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-251-r3] Equipment manual for V-251 (revision r3). Maximum operating temperature: 84 C. Known fault: bearing vibration. The supporting system is S-651. Maintenance owner: electrical.\n[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-21",
      "evidence_tokens": 112,
      "discarded_tokens": 207,
      "support_visible": true,
      "prompt_tokens": 273,
      "output_text_tokens": 62
    },
    {
      "case_id": "F251-03",
      "family": "F251",
      "slice": "follow_up",
      "question": "Shift note. And how hot can this one run?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "V-251",
      "previous_version": "r3",
      "method": "Routed · exact ID first",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "84",
        "evidence": [
          "manual-V-251-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum operating temperature of V-251 is 84°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-251-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-251-r3] Equipment manual for V-251 (revision r3). Maximum operating temperature: 84 C. Known fault: bearing vibration. The supporting system is S-651. Maintenance owner: electrical.\n[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-21",
      "evidence_tokens": 112,
      "discarded_tokens": 207,
      "support_visible": true,
      "prompt_tokens": 278,
      "output_text_tokens": 52
    },
    {
      "case_id": "F210-00",
      "family": "F210",
      "slice": "numeric",
      "question": "When was P-210 last inspected?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "SQL",
      "route": "SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-07-22",
        "evidence": [
          "inventory-P-210-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-07-22",
        "evidence": [
          "inventory-P-210-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "P-210",
            "tenant": "north-yard",
            "inspection": "2025-07-22",
            "version": "r3"
          },
          "evidence": "inventory-P-210-r3"
        }
      }
    },
    {
      "case_id": "F210-03",
      "family": "F210",
      "slice": "numeric",
      "question": "Shift note. Give the last inspection date for P-210.",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "SQL",
      "route": "SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-07-22",
        "evidence": [
          "inventory-P-210-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-07-22",
        "evidence": [
          "inventory-P-210-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "P-210",
            "tenant": "north-yard",
            "inspection": "2025-07-22",
            "version": "r3"
          },
          "evidence": "inventory-P-210-r3"
        }
      }
    },
    {
      "case_id": "F211-00",
      "family": "F211",
      "slice": "numeric",
      "question": "When was F-211 last inspected?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "SQL",
      "route": "SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-08-23",
        "evidence": [
          "inventory-F-211-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-08-23",
        "evidence": [
          "inventory-F-211-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "F-211",
            "tenant": "south-yard",
            "inspection": "2025-08-23",
            "version": "r3"
          },
          "evidence": "inventory-F-211-r3"
        }
      }
    },
    {
      "case_id": "F211-03",
      "family": "F211",
      "slice": "numeric",
      "question": "Shift note. Give the last inspection date for F-211.",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "SQL",
      "route": "SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-08-23",
        "evidence": [
          "inventory-F-211-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-08-23",
        "evidence": [
          "inventory-F-211-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "F-211",
            "tenant": "south-yard",
            "inspection": "2025-08-23",
            "version": "r3"
          },
          "evidence": "inventory-F-211-r3"
        }
      }
    },
    {
      "case_id": "F220-00",
      "family": "F220",
      "slice": "multi_source",
      "question": "Give the last inspection date and supporting system for F-220.",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "graph + SQL",
      "route": "graph + SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-05-05 | S-620",
        "evidence": [
          "inventory-F-220-r3",
          "graph-F-220-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-05-05 | S-620",
        "evidence": [
          "inventory-F-220-r3",
          "graph-F-220-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "F-220",
            "tenant": "north-yard",
            "inspection": "2025-05-05",
            "version": "r3"
          },
          "evidence": "inventory-F-220-r3"
        },
        "graph": {
          "target": "S-620",
          "type": "supported_by",
          "evidence": "graph-F-220-r3"
        }
      }
    },
    {
      "case_id": "F220-03",
      "family": "F220",
      "slice": "multi_source",
      "question": "Shift note. For F-220, which system supports it and when was its most recent inspection?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "graph + SQL",
      "route": "graph + SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-05-05 | S-620",
        "evidence": [
          "inventory-F-220-r3",
          "graph-F-220-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-05-05 | S-620",
        "evidence": [
          "inventory-F-220-r3",
          "graph-F-220-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "F-220",
            "tenant": "north-yard",
            "inspection": "2025-05-05",
            "version": "r3"
          },
          "evidence": "inventory-F-220-r3"
        },
        "graph": {
          "target": "S-620",
          "type": "supported_by",
          "evidence": "graph-F-220-r3"
        }
      }
    },
    {
      "case_id": "F221-00",
      "family": "F221",
      "slice": "multi_source",
      "question": "Give the last inspection date and supporting system for V-221.",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "graph + SQL",
      "route": "graph + SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-06-06 | S-621",
        "evidence": [
          "inventory-V-221-r3",
          "graph-V-221-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-06-06 | S-621",
        "evidence": [
          "inventory-V-221-r3",
          "graph-V-221-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "V-221",
            "tenant": "south-yard",
            "inspection": "2025-06-06",
            "version": "r3"
          },
          "evidence": "inventory-V-221-r3"
        },
        "graph": {
          "target": "S-621",
          "type": "supported_by",
          "evidence": "graph-V-221-r3"
        }
      }
    },
    {
      "case_id": "F221-03",
      "family": "F221",
      "slice": "multi_source",
      "question": "Shift note. For V-221, which system supports it and when was its most recent inspection?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "graph + SQL",
      "route": "graph + SQL",
      "expected": {
        "decision": "answer",
        "value": "2025-06-06 | S-621",
        "evidence": [
          "inventory-V-221-r3",
          "graph-V-221-r3"
        ]
      },
      "response": {
        "decision": "answer",
        "value": "2025-06-06 | S-621",
        "evidence": [
          "inventory-V-221-r3",
          "graph-V-221-r3"
        ]
      },
      "raw": null,
      "route_error": false,
      "covered": true,
      "citation_support": true,
      "exact_value": true,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {
        "inventory": {
          "row": {
            "asset": "V-221",
            "tenant": "south-yard",
            "inspection": "2025-06-06",
            "version": "r3"
          },
          "evidence": "inventory-V-221-r3"
        },
        "graph": {
          "target": "S-621",
          "type": "supported_by",
          "evidence": "graph-V-221-r3"
        }
      }
    },
    {
      "case_id": "F230-00",
      "family": "F230",
      "slice": "ambiguity",
      "question": "What is the maximum temperature for that unit?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "clarify",
      "route": "clarify",
      "expected": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F230-03",
      "family": "F230",
      "slice": "ambiguity",
      "question": "Shift note. When was that pump last inspected?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "clarify",
      "route": "clarify",
      "expected": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F231-00",
      "family": "F231",
      "slice": "ambiguity",
      "question": "What is the maximum temperature for that unit?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "clarify",
      "route": "clarify",
      "expected": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F231-03",
      "family": "F231",
      "slice": "ambiguity",
      "question": "Shift note. When was that pump last inspected?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "clarify",
      "route": "clarify",
      "expected": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "clarify",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F240-00",
      "family": "F240",
      "slice": "boundary",
      "question": "As a guest, show the inventory record for P-240.",
      "role": "guest",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "deny",
      "route": "deny",
      "expected": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F240-03",
      "family": "F240",
      "slice": "boundary",
      "question": "Shift note. Guest request: give inspection date for P-240.",
      "role": "guest",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "deny",
      "route": "deny",
      "expected": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F241-00",
      "family": "F241",
      "slice": "boundary",
      "question": "As a guest, show the inventory record for F-241.",
      "role": "guest",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "deny",
      "route": "deny",
      "expected": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F241-03",
      "family": "F241",
      "slice": "boundary",
      "question": "Shift note. Guest request: give inspection date for F-241.",
      "role": "guest",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "deny",
      "route": "deny",
      "expected": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "response": {
        "decision": "deny",
        "value": "",
        "evidence": []
      },
      "raw": null,
      "route_error": false,
      "covered": false,
      "citation_support": null,
      "exact_value": null,
      "strict_pass": 1,
      "outcome": "Pass",
      "sources": {}
    },
    {
      "case_id": "F200-00",
      "family": "F200",
      "slice": "manual",
      "question": "What is the maximum temperature for V-200?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "87",
        "evidence": [
          "manual-V-200-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature for V-200 is 87°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-200-r3\",\n    \"manual-P-210-r3\",\n    \"manual-F-220-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-220-r3] Equipment manual for F-220 (revision r3). Maximum operating temperature: 71 C. Known fault: seal wear. The supporting system is S-620. Maintenance owner: controls.\n[manual-V-230-r3] Equipment manual for V-230 (revision r3). Maximum operating temperature: 81 C. Known fault: filter blockage. The supporting system is S-630. Maintenance owner: electrical.\n[manual-P-240-r3] Equipment manual for P-240 (revision r3). Maximum operating temperature: 91 C. Known fault: seal wear. The supporting system is S-640. Maintenance owner: mechanical.\n[manual-F-250-r3] Equipment manual for F-250 (revision r3). Maximum operating temperature: 101 C. Known fault: filter blockage. The supporting system is S-650. Maintenance owner: controls.",
      "evidence_tokens": 322,
      "discarded_tokens": 0,
      "support_visible": true,
      "prompt_tokens": 485,
      "output_text_tokens": 73
    },
    {
      "case_id": "F200-03",
      "family": "F200",
      "slice": "manual",
      "question": "Shift note. What's the thermal limit, in C, of V-200?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "87",
        "evidence": [
          "manual-V-200-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The thermal limit for V-200 is not specified.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-200-r3\",\n    \"manual-P-210-r3\",\n    \"manual-F-220-r3\",\n    \"manual-V-230-r3\",\n    \"manual-P-240-r3\",\n    \"manual-F-250-r3\"\n",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-220-r3] Equipment manual for F-220 (revision r3). Maximum operating temperature: 71 C. Known fault: seal wear. The supporting system is S-620. Maintenance owner: controls.\n[manual-V-230-r3] Equipment manual for V-230 (revision r3). Maximum operating temperature: 81 C. Known fault: filter blockage. The supporting system is S-630. Maintenance owner: electrical.\n[manual-P-240-r3] Equipment manual for P-240 (revision r3). Maximum operating temperature: 91 C. Known fault: seal wear. The supporting system is S-640. Maintenance owner: mechanical.\n[manual-F-250-r3] Equipment manual for F-250 (revision r3). Maximum operating temperature: 101 C. Known fault: filter blockage. The supporting system is S-650. Maintenance owner: controls.",
      "evidence_tokens": 322,
      "discarded_tokens": 0,
      "support_visible": true,
      "prompt_tokens": 492,
      "output_text_tokens": 100
    },
    {
      "case_id": "F201-00",
      "family": "F201",
      "slice": "manual",
      "question": "What is the maximum temperature for P-201?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "70",
        "evidence": [
          "manual-P-201-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature for P-201 is 70°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-P-201-r3\",\n    \"manual-F-211-r3\",\n    \"manual-V-221-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-221-r3] Equipment manual for V-221 (revision r3). Maximum operating temperature: 90 C. Known fault: sensor drift. The supporting system is S-621. Maintenance owner: electrical.\n[manual-P-231-r3] Equipment manual for P-231 (revision r3). Maximum operating temperature: 100 C. Known fault: bearing vibration. The supporting system is S-631. Maintenance owner: mechanical.\n[manual-F-241-r3] Equipment manual for F-241 (revision r3). Maximum operating temperature: 74 C. Known fault: sensor drift. The supporting system is S-641. Maintenance owner: controls.\n[manual-V-251-r3] Equipment manual for V-251 (revision r3). Maximum operating temperature: 84 C. Known fault: bearing vibration. The supporting system is S-651. Maintenance owner: electrical.",
      "evidence_tokens": 319,
      "discarded_tokens": 0,
      "support_visible": true,
      "prompt_tokens": 482,
      "output_text_tokens": 73
    },
    {
      "case_id": "F201-03",
      "family": "F201",
      "slice": "manual",
      "question": "Shift note. What's the thermal limit, in C, of P-201?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "",
      "previous_version": "",
      "method": "Routed · all manuals",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "70",
        "evidence": [
          "manual-P-201-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The thermal limit for P-201 is not specified.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-P-201-r3\",\n    \"manual-F-211-r3\",\n    \"manual-V-221-r3\",\n    \"manual-P-231-r3\",\n    \"manual-F-241-r3\",\n    \"manual-V-251-r3\"\n",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-221-r3] Equipment manual for V-221 (revision r3). Maximum operating temperature: 90 C. Known fault: sensor drift. The supporting system is S-621. Maintenance owner: electrical.\n[manual-P-231-r3] Equipment manual for P-231 (revision r3). Maximum operating temperature: 100 C. Known fault: bearing vibration. The supporting system is S-631. Maintenance owner: mechanical.\n[manual-F-241-r3] Equipment manual for F-241 (revision r3). Maximum operating temperature: 74 C. Known fault: sensor drift. The supporting system is S-641. Maintenance owner: controls.\n[manual-V-251-r3] Equipment manual for V-251 (revision r3). Maximum operating temperature: 84 C. Known fault: bearing vibration. The supporting system is S-651. Maintenance owner: electrical.",
      "evidence_tokens": 319,
      "discarded_tokens": 0,
      "support_visible": true,
      "prompt_tokens": 489,
      "output_text_tokens": 100
    },
    {
      "case_id": "F250-00",
      "family": "F250",
      "slice": "follow_up",
      "question": "What is its maximum temperature?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "F-250",
      "previous_version": "r3",
      "method": "Routed · all manuals",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "101",
        "evidence": [
          "manual-F-250-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature of F-250 is 101 C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-F-250-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-220-r3] Equipment manual for F-220 (revision r3). Maximum operating temperature: 71 C. Known fault: seal wear. The supporting system is S-620. Maintenance owner: controls.\n[manual-V-230-r3] Equipment manual for V-230 (revision r3). Maximum operating temperature: 81 C. Known fault: filter blockage. The supporting system is S-630. Maintenance owner: electrical.\n[manual-P-240-r3] Equipment manual for P-240 (revision r3). Maximum operating temperature: 91 C. Known fault: seal wear. The supporting system is S-640. Maintenance owner: mechanical.\n[manual-F-250-r3] Equipment manual for F-250 (revision r3). Maximum operating temperature: 101 C. Known fault: filter blockage. The supporting system is S-650. Maintenance owner: controls.",
      "evidence_tokens": 322,
      "discarded_tokens": 0,
      "support_visible": true,
      "prompt_tokens": 483,
      "output_text_tokens": 52
    },
    {
      "case_id": "F250-03",
      "family": "F250",
      "slice": "follow_up",
      "question": "Shift note. And how hot can this one run?",
      "role": "operator",
      "tenant": "north-yard",
      "previous_asset": "F-250",
      "previous_version": "r3",
      "method": "Routed · all manuals",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "101",
        "evidence": [
          "manual-F-250-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum operating temperature of the F-250 equipment is 101°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-F-250-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-V-200-r3] Equipment manual for V-200 (revision r3). Maximum operating temperature: 87 C. Known fault: seal wear. The supporting system is S-600. Maintenance owner: electrical.\n[manual-P-210-r3] Equipment manual for P-210 (revision r3). Maximum operating temperature: 97 C. Known fault: filter blockage. The supporting system is S-610. Maintenance owner: mechanical.\n[manual-F-220-r3] Equipment manual for F-220 (revision r3). Maximum operating temperature: 71 C. Known fault: seal wear. The supporting system is S-620. Maintenance owner: controls.\n[manual-V-230-r3] Equipment manual for V-230 (revision r3). Maximum operating temperature: 81 C. Known fault: filter blockage. The supporting system is S-630. Maintenance owner: electrical.\n[manual-P-240-r3] Equipment manual for P-240 (revision r3). Maximum operating temperature: 91 C. Known fault: seal wear. The supporting system is S-640. Maintenance owner: mechanical.\n[manual-F-250-r3] Equipment manual for F-250 (revision r3). Maximum operating temperature: 101 C. Known fault: filter blockage. The supporting system is S-650. Maintenance owner: controls.",
      "evidence_tokens": 322,
      "discarded_tokens": 0,
      "support_visible": true,
      "prompt_tokens": 488,
      "output_text_tokens": 55
    },
    {
      "case_id": "F251-00",
      "family": "F251",
      "slice": "follow_up",
      "question": "What is its maximum temperature?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "V-251",
      "previous_version": "r3",
      "method": "Routed · all manuals",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "84",
        "evidence": [
          "manual-V-251-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum temperature of V-251 is 84°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-251-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-221-r3] Equipment manual for V-221 (revision r3). Maximum operating temperature: 90 C. Known fault: sensor drift. The supporting system is S-621. Maintenance owner: electrical.\n[manual-P-231-r3] Equipment manual for P-231 (revision r3). Maximum operating temperature: 100 C. Known fault: bearing vibration. The supporting system is S-631. Maintenance owner: mechanical.\n[manual-F-241-r3] Equipment manual for F-241 (revision r3). Maximum operating temperature: 74 C. Known fault: sensor drift. The supporting system is S-641. Maintenance owner: controls.\n[manual-V-251-r3] Equipment manual for V-251 (revision r3). Maximum operating temperature: 84 C. Known fault: bearing vibration. The supporting system is S-651. Maintenance owner: electrical.",
      "evidence_tokens": 319,
      "discarded_tokens": 0,
      "support_visible": true,
      "prompt_tokens": 480,
      "output_text_tokens": 51
    },
    {
      "case_id": "F251-03",
      "family": "F251",
      "slice": "follow_up",
      "question": "Shift note. And how hot can this one run?",
      "role": "operator",
      "tenant": "south-yard",
      "previous_asset": "V-251",
      "previous_version": "r3",
      "method": "Routed · all manuals",
      "expected_route": "manual",
      "route": "manual",
      "expected": {
        "decision": "answer",
        "value": "84",
        "evidence": [
          "manual-V-251-r3"
        ]
      },
      "response": {},
      "raw": "```json\n{\n  \"decision\": \"The maximum operating temperature of V-251 is 84°C.\",\n  \"value\": null,\n  \"evidence\": [\n    \"manual-V-251-r3\"\n  ]\n}\n```",
      "route_error": false,
      "covered": false,
      "citation_support": false,
      "exact_value": false,
      "strict_pass": 0,
      "outcome": "No usable JSON object",
      "context": "[manual-P-201-r3] Equipment manual for P-201 (revision r3). Maximum operating temperature: 70 C. Known fault: sensor drift. The supporting system is S-601. Maintenance owner: mechanical.\n[manual-F-211-r3] Equipment manual for F-211 (revision r3). Maximum operating temperature: 80 C. Known fault: bearing vibration. The supporting system is S-611. Maintenance owner: controls.\n[manual-V-221-r3] Equipment manual for V-221 (revision r3). Maximum operating temperature: 90 C. Known fault: sensor drift. The supporting system is S-621. Maintenance owner: electrical.\n[manual-P-231-r3] Equipment manual for P-231 (revision r3). Maximum operating temperature: 100 C. Known fault: bearing vibration. The supporting system is S-631. Maintenance owner: mechanical.\n[manual-F-241-r3] Equipment manual for F-241 (revision r3). Maximum operating temperature: 74 C. Known fault: sensor drift. The supporting system is S-641. Maintenance owner: controls.\n[manual-V-251-r3] Equipment manual for V-251 (revision r3). Maximum operating temperature: 84 C. Known fault: bearing vibration. The supporting system is S-651. Maintenance owner: electrical.",
      "evidence_tokens": 319,
      "discarded_tokens": 0,
      "support_visible": true,
      "prompt_tokens": 485,
      "output_text_tokens": 52
    }
  ],
  "batch_timings": [
    {
      "method": "Corpus prefix",
      "case_ids": [
        "F200-00",
        "F200-03",
        "F201-00",
        "F201-03"
      ],
      "wall_ms": 4954.18409499996,
      "peak_allocated_bytes": 3205916160,
      "input_tokens": 1114,
      "output_text_tokens": 244
    },
    {
      "method": "Exact ID first",
      "case_ids": [
        "F200-00",
        "F200-03",
        "F201-00",
        "F201-03"
      ],
      "wall_ms": 4646.265760999881,
      "peak_allocated_bytes": 3205916160,
      "input_tokens": 1114,
      "output_text_tokens": 244
    },
    {
      "method": "All tenant manuals",
      "case_ids": [
        "F200-00",
        "F200-03",
        "F201-00",
        "F201-03"
      ],
      "wall_ms": 7090.543519999983,
      "peak_allocated_bytes": 3285371904,
      "input_tokens": 1948,
      "output_text_tokens": 346
    },
    {
      "method": "All tenant manuals",
      "case_ids": [
        "F250-00",
        "F250-03",
        "F251-00",
        "F251-03"
      ],
      "wall_ms": 4983.75503200009,
      "peak_allocated_bytes": 3283963904,
      "input_tokens": 1936,
      "output_text_tokens": 210
    },
    {
      "method": "Exact ID first",
      "case_ids": [
        "F250-00",
        "F250-03",
        "F251-00",
        "F251-03"
      ],
      "wall_ms": 4598.197554999842,
      "peak_allocated_bytes": 3204571136,
      "input_tokens": 1102,
      "output_text_tokens": 237
    },
    {
      "method": "Corpus prefix",
      "case_ids": [
        "F250-00",
        "F250-03",
        "F251-00",
        "F251-03"
      ],
      "wall_ms": 5220.377899999903,
      "peak_allocated_bytes": 3204571136,
      "input_tokens": 1102,
      "output_text_tokens": 178
    }
  ]
}